Type tests and environmental conditions – Westermo FDV-206-1D-1S User Manual
Page 6
6
6660-2201
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
± 6 kV
Enclosure air
± 8 kV
RF field AM modulated EN 61000-4-3
Enclosure
20 V/m 80% AM (1 kHz), 80 – 2 700 MHz
Fast transient
EN 61000-4-4
Signal ports
± 2 kV
Power ports
± 2 kV
Surge
EN 61000-4-5
Signal ports unbalanced
± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced
± 2 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Pulse magnetic field
EN 61000-4-9
Enclosure
300 A/m, 6.4 / 16 µs pulse
Voltage dips and
interruption
EN 61000-4-29
DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class A
FCC part 15
Class A
Conducted emission
EN 55022
AC power ports
Class B
FCC part 15
AC power ports
Class B
EN 55022
DC power ports
Class B
Dielectric strength
EN 60950
Signal port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Power port to other
isolated ports
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)
Temperature
Operating
–20 to +70ºC
Storage & Transport
–40 to +85ºC
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2000 m / 70 kPa
Reliability prediction
(MTBF)
MIL-HDBK- 217F
Operating
580 000 hours @ 25°C
Service life
Operating
10 year
Vibration
IEC 60068-2-6
Operating
5 – 20 Hz: 2 m²/s³
20 – 200 Hz: – 3 dB/oct
3 axis = 3 * 30 min
Shock
IEC 60068-2-27
Operating
6 ms 1000 m/s²
6 directions, 3 shocks / direction
Enclosure
UL 94
PC / ABS
Flammability class V-1
Dimension W x H x D
52.5 x 100 x 101 mm
Weight
0.6 kg
Degree of protection
IEC 529
Enclosure
IP 40
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail