Fsk analysis – Wavecom W74PC V8.7.0 User Manual
Page 95

WAVECOM Decoder W74PC, W-PCI/e, W-CODE, W-CLOUD Manual V8.7.0
Analysis Tools
85
The Trigger Mode option allows the real-time
oscilloscope to trigger on the Positive or the
Negative slope or to be switched Off.
The Trigger Level option allows conventional
level driven triggering to be set. The un-
calibrated input voltage range is from +99%
to –99%.
The vertical sensitivity may be set with the
option Time/Div. Nine predefined values are
available covering a range from 200
s to 100
ms per division.
Using the Oscilloscope Gain option, the hori-
zontal un-calibrated input voltage sensitivity
may be adjusted from 0% to 100%.
FSK Analysis
The FSK analysis mode is an important tool to measure the baud rate and frequency shift of FSK transmis-
sions. The magnitude of these property values may help to identify the transmission being monitored.