Instruction handbook – Watson-Marlow PF6 User Manual
Page 27

INSTRUCTION HANDBOOK
PF6
PF6 IH EN 74-105-022 v1.04.doc
Version: 1.04
Page 27 of 30
Step
Action
Remarks / control
4.
Adjust the screws (B) for control of maximum pressure.
The outlet air pressure should be adjusted to 3.0 – 3.5 bar.
5
Should it become necessary to put in new glue, use a “soft”
glue like Loctite 222.