Watson-Marlow 323Du User Manual
Page 22
Watson-Marlow 323E, 323S, 323U and 323Du User Manual
22
16 MemoDose
The pump can dispense a set quantity or dose of fluid each time the key is pressed.
This is the MemoDose facility.
Set the pump
speed and direc-
tion. Place a suit-
able measuring
container at the
outlet and
START the pump.
When the required vol-
ume of fluid has been
dispensed, press the
STOP key twice within
half a second. This
starts the MemoDose
feature.
The pump has made a record of the fluid it has just dispensed.
You may now repeat this dose or adjust the quantity as required.
The display will show “dos“ for 3 seconds. Then the display will
change to show 100%.
S, U, Du
Measure the quantity of fluid which has been dispensed. If the quantity is
correct press START to repeat the dose.
If the initial dose is larger than required use
the DOWN key to reduce the volume %
showing on the display. This will reduce the
next dose to be dispensed by the pump.
If the initial dose was smaller than
required use the UP key to increase
the next dose to be dispensed by
the pump.
Press START. The pump will dispense the new dose
and the display will count down as this dose proceeds.
The pump will stop when the new dose is complete.
Measure the new dose. If it is correct you may now
repeat this dose as often as required. The keypad
lock can be used to prevent further changes.
Use the UP and DOWN keys to further adjust the
dose until the correct quantity is obtained. You may
adjust the dose size down to 1% or up to 999%
Press the STOP key twice within half a second to exit MemoDose
and return to manual operation.