beautypg.com

12 switching the pump on, 11 start-up check list – Watson-Marlow 323Du User Manual

Page 18

background image

Watson-Marlow 323E, 323S, 323U and 323Du User Manual

18

E, S, U, Du

E, S, U, Du

12 Switching the pump on

Switch on the power supply at the rear of the pump. The pump runs a power-on
test to confirm proper functioning of the memory and hardware. If a fault is
found, an error message is displayed. See 19 Error messages.
If the pump starts running look for the ! symbol on the display. This ! symbol in-
dicates that the pump is set for auto-restart. Press the STOP key if you need to
stop the pump

11 Start-up check list

Ensure that proper connections are achieved between the pump tube and
suction and discharge piping.
Ensure proper connection has been made to a suitable power supply.
Ensure that the recommendations in section 9 Good pump installation practice
are followed.
Check the position of the voltage selector switch
Check the mains power switch at the rear of the pump
Check the fuse in the mains inlet socket at the rear of the pump
Ensure that the mains IEC plug is correctly fitted in the mains IEC inlet socket

First-time start-up defaults

323E

323S

323U

323Du

Direction

Clockwise

Clockwise

Clockwise

Clockwise

Pumphead, 400
Pumphead, 220

313

313

501RL

313

501RL

313

501RL

Keypad lock

Off

Off

Off

Auto-restart

Off

Off

Off

Pump status

Stopped

Stopped

Stopped

Stopped

Remote stop

Open=run

Open=run

The pump is now ready to operate according to the defaults listed above.

All operating parameters may be changed by means of key-presses. See 14 Manual
operation
.