10 specifications, 1 pump head, 1 performance – Watson-Marlow Bredel 40 User Manual
Page 56

SPECIFICATIONS
56
10
SPECIFICATIONS
10.1
Pump head
10.1.1 Performance
Description
Bredel
40
Bredel
50
Bredel
65
Bredel
80
Bredel
100
Max. capacity, continuous [m
3
/h]
6.0
10.5
20.0
28.0
36.0
Max. capacity, intermittently [m
3
/h]
*
*
Intermitted duty: Let the pump stand still to cool down for at least 1 hour after 2 hours of
operation.
9.6
17.5
32.0
42.0
60.0
Capacity per revolution [l/rev]
1.33
2.9
6.7
11.7
20.0
Max. permissible working pressure [kPa]
1600
Permissible ambient temperature [°C]
-20 to +45
Permissible product temperature [°C]
-10 to +80
Sound level on 1 m [dB(A)]
70