INSTALLATION
21
5
INSTALLATION
5.1
Unpacking
When unpacking carefully follow the instructions as
given on the packaging or on the hose pump.
5.2
Inspection
Check that your delivery is correct and check it for any
transport damage. Refer to §
. Report any damage
immediately to your Bredel representative.
5.3
Installation conditions
5.3.1
Ambient conditions
Make sure that the hose pump is in an area where the
ambient temperature during operation is not lower than
-20 °C and not higher than +45 °C.
5.3.2
Set-up
•
The pump materials and protective layers are
suitable for indoor set-up and a protected
outdoor set-up. Under certain conditions the
pump is suitable for limited outdoor set-up or a
salty or aggressive atmosphere. Consult your
Bredel representative for more information.
•
Make sure that the floor surface is horizontal
and has a maximum slope of 10 mm per metre.
•
Make sure that there is sufficient room around
the pump to carry out the necessary
maintenance activities.
•
Make sure that the room is sufficiently
ventilated, so that the heat developed by the
pump and drive can be discharged. Keep some
distance between the ventilation cover of the
electric motor and wall to enable the supply of
necessary cooling air.