5.11 Maintenance / Repair

The Filling of the pump is only permitted outside the explosion aria. Tools that are used should in compliance with ATEX.

The pump aggregate always needs to be kept clean of dust with a damp cloth to prevent the dust from smouldering.

The rinsing channels in the power frame must always be checked for blockages and if necessary cleaned.

5.12 Cleaning

Caution! No solvent cleaning agents may be used to clean the pump as this could create an uncontrollable explosive atmosphere.

5.13 Medium to be pumped

Chemicals that are combustible below the temperature 120 degrees Celsius and Carbon disulphide must not be pumped.

5.14 Coupling

If the pump is used in an explosion-risk area, the pump must only be coupled to the drive by means of an elastic, positive coupling with
ATEX certification, at least corresponding to the supplied pump. Chains, toothed belts, v-belts or similar equipment which may transmit
radial forces on the bearings should not be used.

5.15 Drive

Any preceding reduction gears and/or control units must have the corresponding ATEX certification, at least corresponding to the
supplied pump. Combustion engines must never be used!
For operation with a frequency converter, this must either be installed outside the ex-zone, or have the same ATEX certification
corresponding to the delivered pump. In any case the converter must have the properties required for operation in ex-zones, for
example, temperature monitoring, speed limitation, etc.

6

Warranty and liability

Basically our “General sales and delivery conditions” apply.
These are available to the operator at the latest since conclusion of the contract.

Warranty and liability claims for personal and material damage are excluded if they are attributable to one or several of the following
causes:

• Use of the machine not as intended
• Incorrect installation, operation and maintenance of the machine
• Operating the machine with defective safety devices or not correctly attached or not functioning safety and protective devices
• Non-compliance with the instructions in the operating instructions regarding

transport,

storage,

installation,

start-up,

operation, maintenance and setting of the machine.

• Unauthorized constructional changes to the machine
• Insufficient monitoring of machine parts subject to wear
• Incorrectly performed repairs
• Cases of catastrophe due to effect of foreign bodies and acts of God.


Watson-Marlow MasoSine

grants no warranty on this documentation as well as no implicit warranties on customary quality and

suitability for a certain application.
The Watson-Marlow MasoSine

undertakes no liability for errors contained in it or consequential damage occurring by chance arising

due to the design, performance and the use of this documentation.
This publication contains own information protected by copyright. All rights are reserved.
This publication may be neither photocopied, nor duplicated nor translated without previous agreement of The Watson-Marlow
MasoSine
. Rights reserved to make changes in these operating instructions.

7

Transport instructions

The choice of the means of transport is according to the size of the pump and of the drive. The pump must be suspended correctly for
transport. The crane/forklift truck and the ropes/belts must be sufficiently dimensioned. If the pump is transported with a lift truck or a
forklift truck, it must be noted that the console centre point is not automatically the centre of gravity.

wrong right