15.3 Manual cleaning
Manual cleaning of the pump can be performed after complete dismantling of the pump.
Pay attention to parts sensitive to breakage!!
If the pump is stopped during the process and opened for the purpose of cleaning or checking,
the responsible fitter or electrician must be notified to undertake suitable measures so that the pump
cannot be put into operation (remove fuses, notify electrician).
The pump may also never be put into operation if the housing cover is removed. Should the pump
not yet be connected to the piping system, then reliable care must be taken that the drive machine
cannot be switched on.
Observe the accident prevention regulations!!
15.4 Sterilisation
Sterilization of the pump with standard equipment is possible up to 110°C only in standstill!
In the case of special equipment of the pump or higher temperatures, please always firstly consult the manufacturer!
16 Heating / cooling
Front housing
Pump housing
17 Lubrication
The first filling with a corresponding grease lubricant (such as
MOLYDUVAL Soraja C532, DIN 51502, +180°C to –20°C
according to
FDA
Reg.
21CFR178.3570
or
ESSO
multipurpose grease NLGI K2-K30) is made at MASO.
However, the filling amount should be checked regularly and
replenished if necessary. For this purpose unscrew the vent
valve and refill with grease through the lubricating nipple - until
it escapes through the vent bore. If the valve is not
unscrewed before this process, damage to the radial shaft
sealing rings cannot be ruled out! After ending filling simply
screw the vent valve back on!
18 Disposal
Send the used oil or used grease for recycling.
19 Spare parts
Basically repairs should be performed only by factory personnel or by customer service organizations authorized by the factory. If you
perform the work yourself, observe the relevant safety regulations and contact the factory customer service before starting the work,
especially if there are still warranty obligations that can be lost due to not approved interventions.
Only original Watson-Marlow MasoSine spare parts may be used.
You should record changes in the fixtures and fittings, for example another sealing
system or a material change, in writing.
Please provide all information on orders:
- Pump number - Material
- EDP number - Quantity
- Article Ask for our express delivery !
There is a crescent-shaped channel milled into the
housing which is sealed later by a stainless steel
plate. There are connections on two sides through
which the heating or cooling agent flows. Counter-
pressure should not exceed 1 bar. You can dictate
temperature and pumping rate by the heating or
cooling agent.
The cooling/heating agent should enter the
system at the lowest point.
If a heater is to be used at the pump, the
temperature must be clarified with the
manufacturer!