Remedy

Rotor has wear on one side

Rotor not tightened correctly on
installation

Tighten Shaft Nut firmly on block

Adjusting dimensions changed after
working on the Bearing Housing

Check and correct the adjusting
dimensions
SPS 600 = 27,5 mm + 0,1 mm

Pump not clean after CIP
cleaning

Cleaning regulation not complied
with

Choke on the pressure side
Check differential pressure 3-4
bar

Rotor has seized on Liner

Rotor not correctly tightened

Tighten Shaft Nut firmly on block

Temperature too high
(thermal expansion)

Choose Liner with larger
tolerances

Purging between housing
and Power Frame leaking

O-ring in the power frame missing or
defective

Install or replace O-ring

Water or pumped material
in the Bearing Housing

Purging pressure too high

Purging must be pressureless
(attach pressure reducer, max.
0.1 bar)

Leakage bores closed

Check leakage bores for free
passage, replace shaft seals on
pump and power frame

Front Support has seized
on Rotor

O-ring in the front bearing missing or
worn

Install or replace O-ring

Front bearing wrongly installed

Examine front bearing for
damage and install in correct
position

Product is leaking from the
Bearing Housing openings

Sealing system in the pump is
leaking

Inspect and if necessary replace
the sealing system and clean the
rinsing channels

Pump aggregate subject to
vibrations

Speed of the (drive) motor is too
high

Lower the speed of the (drive)
motor

Smells and smoke coming
from the pump

Pump is running dry

Stop the pump immediately.
Check inner parts for damage
and replace if necessary

Corrosion

Corrosion occurs

Eliminate corrosion and varnish
or use spray oil