beautypg.com

Watson-Marlow 900 Series User Manual

Page 9

background image

Page

9

Locate the upper port connector

with the securing nuts and the

Allen key supplied.
Rotate the rotor anticlockwise and

drive the other end of the tube out

of the lower casing port. Locate

the support ring, compression

gland and compression ring.
Locate the lower port connector

using the securing nuts and Allen

key supplied.

Replace the lubricant drainage

plug then fill the pumphead with

lubricant to the specified volume.

The window in the pumphead door

is a motion window and provides a

visual indication of the rotation of

the rotor within the pumphead.

This window should not be used

as lubricant level indicator.

Locate and secure the lubricant

filler plug.

Manual tube removal

Isolate the motor from the

mains supply before opening

the pumphead door.

Place a container under the

pumphead, then remove the

lubricant drainage plug and the

lubricant filler plug. Allow the

lubricant to drain from the

pumphead.

Remove the four door locking

screws with the Allen key

supplied. Swing the pumphead

door open.