Powered tube removal

Place a container under the

pumphead, then remove the

lubricant drainage plug and the

lubricant filler plug. Allow the

lubricant to drain from the

pumphead.




Loosen and remove the four

securing nuts on the lower casing

port connector using a 13mm

spanner.




If the pump is a variable speed

unit, run at a slow speed. Run the

pump anticlockwise until the

support ring, compression gland

and the compression ring are

outside of the pump.
Stop the pump and with two

levers, lever the connector out of

the tube, then slide off the support

and compression rings and the

compression gland. Remove the

four securing nuts on the upper

casing port connector using a

13mm spanner.


Reverse the direction of rotation of

the rotor to allow the tube to be

driven out of the pumphead.
Remove the four door locking

screws using the Allen key

supplied.