beautypg.com

Watson-Marlow 900 Series User Manual

Page 8

background image

Page

8

Isolate the motor from the

mains supply before opening

the pumphead door.

Swing the pumphead door open.

Remove the tube from the

pumphead.

Check that there is no debris

inside the casing and that it is

clean. Check that the front casing

lubricant seal is not damaged,

then secure the door with the four

door locking screws and the Allen

key supplied ensuring the seal is

seated correctly.

Powered tube fitting

Isolate the motor from the

mains supply before opening

the pumphead door.

Close and lock the pumphead

door with the four door locking

screws and Allen key supplied.

Take a new piece of tubing and

smear Silicone grease or tube

lubricating oil on the outside of the

tube. Connect motor to the mains

supply. Start the pump and with

care, feed the tube into the

pumphead following the

anticlockwise rotation of the rotor.

Continue feeding until the other

end of the tube is level with the

pump face. Stop the motor.

Slide the support ring (the shortest

ring), compression gland and the

compression ring (which has a

step to allow ease of location into

the tube port) onto the tube. Push

the connector into the pipe.

Repeat for the other end of the

tube.

Connector ➁ Compression ring

Support ring ➃ Tube

Compression gland