1-2

General

2048 PMU/NTU

1.1

Design Highlights

End-to-end user control and access to
extensive unit performance data
unit configuration
unit status (normal, looped, alarm)

AMI or HDB3 coding

User and PTT access via FDL link

Dual performance registers - User and PTT/carrier

Jitter control of network signal (per G.823)

Complete diagnostic capabilities, including multiple
loopbacks and built-in BERT

Front panel test jacks, alarm indicators, and test switch

1.2

Specifications

Network Interface

Line Rate:

2.048 Mb/s, ± 50 ppm, PCM-30

Multi-frame Type:

CAS and/or CRC4, or none

Line Code:

AMI or HDB3

Connection:

120 ¾ balanced or 75 ¾ unbalanced

Backplane:

DB15, Twin-axial, and BNC options

Output Signal:

75 ¾ mark 2.37 V, space 0 ± 0.237 V

(per G.703)

120 ¾ mark 3 V, space 0 ± 0.3 V

Line Build Out:

0, -7.5, -15 dB switch settings

Input Signal:

75 ¾ mark 2.37 V, space 0 ± 0.237 V

(per G.703)

120 ¾ mark 3 V, space 0 ± 0.3 V
attenuated by 0 to -27 dB (ALBO)

Jitter Attenuation:

per CCITT G.823

AIS:

Unframed or framed all ones, or

(user selectable)

line loopback

Overvoltage:

1000 V minimum protection

Equipment Interface

Line Rate:

2.048 Mb/s, ± 50 ppm, PCM-30

Multi-frame Type:

CAS and/or CRC4, or none

Line Code:

AMI or HDB3

Output Signal:

75 ¾ mark 2.37 V, space 0 ± 0.237 V

(per G.703)

120 ¾ mark 3 V, space 0 ± 0.3 V

Pulse Width:

244 ns, nominal

DTE Input Signal:

75 ¾ mark 2.37 V, space 0 ± 0.237 V

(per G.703)

120 ¾ mark 3 V, space 0 ± 0.3 V
attenuated by 0 to -6 dB at
1024 kHz (0 dB = 2.4 V)

Connection:

120 ¾ balanced or 75 ¾ unbalanced

Backplane:

DB15, Twin-axial, and BNC options

AIS:

Unframed or framed all ones, or
line loopback

Overvoltage:

1000 V minimum protection

Diagnostics

Line Loopback:

Signal regeneration only

Payload Loopback:

Signal regenerated with new frame
synchronization and CRC4

BERT:

63, 511, 2047, 2

15

(default), 2

20

,

2

23

, QRW, and ALT

BERT Activation:

Front panel switch for test. User
selection of BERT patterns via
command. Pattern sync and bit
errors reported via command.

Loopback Control:

Inband loop up, 00001 for Ý 5 sec
Inband loop down, 001 for Ý 5 sec
User enable/disable
Manual loopback switch
FDL loopback command

PTT and EM8000

Full ESF performance monitoring
through a terminal port (6-pin RJ11),
and via FDL in selected national bit

Jack Access

Toward Network:

Bantam jacks (In, Out, and Monitor)

Toward DTE:

Bantam jacks (In, Out, and Monitor)

Access Ports

User Net Manager:

Asynchronous, RS232

Telco Net Manager:

Asynchronous, RS232

Local Access:

Asynchronous, RS232

Bit Rates:

1200, 2400, 9600 or 19200 b/s

(all ports)

(switch selectable)

Formats:

8 data bits, 1 stop bit, no parity