5

12

Specifications

Network Interface

Line Rate:

1.544 Mbps (± 50 bps)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Line Impedance:

balanced 100

(± 5%)

Input Signal:

DS1, +1 to -27 dB (ALBO)

Output Signal:

3.0 V (±15%) base-peak into 100

Line Build Out:

0, -7.5, -15, and -22.5 dB attenuation

Line Protection:

1000 V lightning, input/output

Jitter Control:

per TR62411 and T1.403

Pulse Density:

per TR62411

V.35 Interface

Data Rate:

Synchronous, N x 56 or N x 64 kbps

Clocking:

Internal or external

Industry Standards

FCC:

Part 15 Subpart B, Class A

UL

1459 2

nd

Edition

CSA:

C22.2 No. 225-M90

IC:

CSO3 Issue 8

ANSI T1.403:

1989 (300 only)

TR54016:

September 1989 (300 only)

TR62411:

December 1990

TR54019A: April

1988

Power

AC Power:

115 VAC (± 10%), 150 mA max, 20 Watts, 73 BTU max.

Connection:

5-foot power cord

Mechanical

Mounting:

Desktop, wall, or vertical rack

Dimensions:

1.75 inches (4.45 cm) high, 6.8 inches (17.27 cm) wide, 10.5
inches (26.67 cm) deep

Weight:

2 pounds (0.91 kg)

Environmental

Operating Temp:

32° to 122°F (0° to 50° C)

Storage Temp:

-4° to 185°F (-20° to 85° C)

Humidity:

95% max (non-condensing)

unit generates a PRM (performance report message) once every second and responds to
T1.403 messages only.

A - ESF

B - D4

Network Coding: Position S2-5 sets the network line code format. With AMI coding,
each unit converts data to the AMI format from the DTE port towards the network. In-
coming AMI data is converted internally to NRZ data and passed to the DTE port. In
the B8ZS mode, the unit substitutes any 8-zero data with a B8ZS code and transmits it
towards the network. B8ZS data from the network is converted to NRZ data internally.
When the unit is operating ‘clear channel’, it can be configured to B8ZS for ones den-
sity control.

A - AMI

B - B8ZS

Network LBO: Positions S2-6 and S2-7 set the network line build out signal level of
data transmitted towards the T1 facility. The output level is factory set at 0 dB. It may
be attenuated by - 7.5 dB, -15 dB, or -22.5 dB if operating conditions require the
change (refer to the Switch S2 diagram for switch settings). The telco should provide
the proper setting to the user. If unsure of the exact setting, then let it remain at 0 dB.

Connections

The model 300 and 310 rear panels have two interface connectors - an RJ-48C network
interface connector and a V.35 high speed port connector. The following paragraphs ex-
plain the network and V.35 connections. Each unit comes equipped with a power cord
for 115 VAC (±10%) operation.

V.35 Port Connection

The V.35 port meets all the general physical and electrical requirements. It supports
TM and auto clock scan. The V.35 pin assignments are as follows.

Circuit

Pin #

Signal Name

DCE

101

A

Frame Ground

Ground

102

B

Signal Ground

Ground

103

P /S

Transmit Data

In

104

R /T

Receive Data

Out

105

C

Request To Send

In

106

D

Clear To Send

Out

107

E

Data Set Ready

Out

109

F

Data Carrier Detect

Out

113

U /W

External Transmit Clock

In

114

Y /AA

Transmit Clock

Out

115

V /X

Receive Clock

Out

142

K

Test Mode

Out