1.1
Specifications
Network Interface
Line Rate:
1.544 Mb/s (± 50 bps)
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
Ω
(± 5%)
Input Signal:
DS1, +1 to -30 dB (ALBO)
Output Signal:
3.0 V, ±15%, base-peak into 100 ¾
Line Build Out:
0, -7.5, -15, and -22.5 dB attenuation
Line Protection:
1000 V lightning, fused input/output
Jitter Control:
per TR62411 and T1.403
Pulse Density:
per TR62411
Equipment Interface
Line Rate:
1.544 Mb/s (± 50 bps)
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
Ω
(± 5%)
Input Signal:
DSX1 to 655 feet
Output Signal:
Selectable DSX1 signal level from 0 to 655 feet
Line Protection:
1000 V lightning, input/output
DTE Line Coding: Position S2-3 sets the DTE line coding, including conversion.
A - AMI
B - B8ZS
Network Line Framing: Position S2-4 sets the CSU to the framing of the network
line. In the ESF mode, the unit responds to all T1.403 or 54016 messages.
A - ESF
B - D4
DTE Line Framing: Position S2-5 sets the CSU to the framing of the DTE line.
A - ESF
B - D4
PRM: Position S2-7 enables/disables sending a PRM (performance report message)
during AIS. If the unit detects a loss of sync from the DTE, an unframed all ones signal
is generated to the T1 facility. If Switch S2-1 is set for T1.403 operation, the unit inter-
rupts the AIS signal with a PRM once a second.
A - PRM enabled
B - PRM disabled
TxPORT 210 CSU
M
ode
NE
T
DT
E
NE
T
DT
E
Sp
ar
e
PR
M
5
4
3
2
1
6
7
M
ode
NE
T
DT
E
NE
T
DT
E
Sp
ar
e
PR
M
540
16
AM
I
AM
I
ES
F
ES
F
En
ab
le
T
1
.403
B8ZS
B8ZS
D4
D4
Dis
able
A
B
LOOP
NORM
CSU
PWR
DTE
NET
LOOP
PRODUCTIVITY
SERI ES
210
T
R
A
N
S
P
O
R
T
®
Configuration Switch S2
Note: This switch
is provided only on
the 200 CSU