Verilink 2010 (34-00204) Product Manual User Manual
Page 5

1-2
General
2010 CSU
Equipment Interface
Line Rate:
1.544 Mb/s (±50 bps)
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
Ω
(±5%)
Input Signal:
DSX1 to -6 dB
Output Signal:
Selectable DSX1 level from 0 to 655
feet in 4 incremental levels
Line Protection:
1000 V lightning, fused input/output
Mechanical
Stand-alone Unit:
Mounting:
desktop, wall, horizontal rack, or
vertical rack
Dimensions:
1.72" W, 6.8" H, 10.5" D
Weight:
2 lbs.
12 - slot Chassis:
Mounting:
19" rack (23" available)
Dimensions:
19" W, 7" H, 10.5" D
Weight: 9.5
lbs.
Environmental
Operating Temp:
0° to 50° C (32° to 122°F)
Storage Temp:
-20° to 85° C (-4° to 185°F)
Humidity:
95% max (non-condensing)
Compatibility
TR54016
September 1989
TR62411
ANSI T1.403
Industry Standards
FCC Compliance:
Part 15, Subpart B, Class A
FCC Part 68 Reg:
FXKUSA- 75690-DE-N
UL Approved
CSA Certified:
LR62298
DOC /CSO3:
1653 5649 A
1.2
FCC Requirements
WARNING: Changes or modifications to
this unit not expressly approved by the party
responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC rules. Opera-
tion is subject to the following two conditions:
1)
This device may not cause harmful interference.
2)
This device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment
is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and
if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communi-
cations. Operation of this equipment in a residential area is
likely to cause harmful interference. The user will be
required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure com-
pliance with the Class A FCC limits.
Notice to Users of 1.544 Mb/s Service: The following
instructions are provided to ensure compliance with FCC
Rules, Part 68:
1)
All direct connections to T1 lines must be made using
standard plugs and jacks.
2)
Before connecting your unit, you must inform the local
telephone company of the following information:
Port ID: P/N/12 - 00635
REN/SOC: 6.0 N
FIC (Facility Interface Code):
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
04DU9-1ZN
USOC jack:
RJ48C (stand-alone version)
RJ48H (chassis version)
3)
If the unit appears to be malfunctioning, it should be
disconnected from the telephone lines until you learn
whether the source of trouble is your equipment or the tele-
!