Verilink 2010 (34-00204) Product Manual User Manual
Page 15
![background image](https://www.manualsdir.com/files/808485/content/doc015.png)
3-4
Operation
2010 CSU
totals for the last 24 -hour period (or the last 96 fifteen-
minute intervals).
The remaining lines of this screen show the data for any of
the intervals that contained errors. Interval 1 is the most
recently stored interval and interval 96 is the oldest 24 -hour
interval. The real time of the interval beginning is shown in
the first column.
If more than five errored intervals have elapsed,
[PAGE -
DN]
appears to the left of the performance data. Pressing
[PAGE -UP]
appears once
[PAGE - DN]
is used. Pressing
[PAGE - UP]
displays the previous five errored
intervals. Only intervals that contained errors are displayed,
which eliminates rows of zeroes. If an interval is not dis-
played, no errors were detected during that time period.
NOTE: The parameters shown on the ‘Performance’
screens are updated at 5 second intervals.
Per AT&T Technical Reference TR54016, the ‘
Stan-
dard 24
Hour
’ performance data consists of Errored Sec-
onds (ES), Bursty Errored Seconds (BES), Severely Errored
Seconds (SES), Unavailable Seconds (UAS), Loss of Frame
Count (LOFC), and Controlled Slip Seconds (CSS).