beautypg.com

Delta Electronics FFB0412EHN User Manual

Dimensions drawing, P & q curve, Mounting panel cutout

background image

UH
GH

EH

FFB0412XN-C

(M /MIN)

32.0

(IN H O)

2

Air Pressure

0.45

.20

8.0

(mm H O)

0

12

0

0

2

0

Air Flow

16.0

24.0

.60

.40

.80

36

24

0.90

1.35

60

48

1.80

2.25

72

2.70

1.0

(CFM)

3

(INCH)

UNIT :

mm

LABEL

40.0±0.5

32.0±0.3

(1.260±0.012)

(1.575±0.020)

(1.575±0.020)

40.0±0.5

32.0±0.3

(1.260±0.012)

(8-Ш0.138±0.012)

8-Ш3.5±0.3

338.0±10.0

(13.310±0.394)

10.0

(0.394)

(1.102±0.020)

28.0±0.5

(0.157±0.016)

4.0±0.4

(INCH)

UNIT : mm

(1.512)

38.4

(1.512)

38.4

(1.260)

32.0

(1.260)

32.0

38.4 (1.512) 32.0 (1.260)

38.4 (1.512) 32.0 (1.260)

Ш40.8

(Ш1.606

Ш40.9

(Ш1.610)

(4-Ш0.138)

4-Ш3.5

(4-Ш0.138)

4-Ш3.5

OUTLET SIDE

INLET SIDE

http://www.deltaww.com

FFB

DIMENSIONS DRAWING

40 x 40 x 28 MM SERIES

*

Bearing Type

Ball Bearings

*

Material

Impeller & Frame : Plastic(UL 94V-0)

*

Lead Wires :

UL 1061 AWG #26 OR Equivalent

Red Wire Positive(+)

Black Wire Negative(-)

*

Weight : 47g (1.66 OZ)

MODEL

Rated

Voltage

Operating

Voltage

Range

Rated

Current

Rated

Input

Power

Speed

Maximum

Air Flow

Maximum

Air Pressure

Noise

PART NO.

REV. FUNCTION

VDC

VDC

Amp

Watt

R.P.M. m

3

/min

CFM

mmH

2

O

IN H

2

O

dB-A

FFB0412EHN

-C -R00 / -F00

12

5.5 to 13.2

0.33

3.96

14500

0.576

20.34

31.28

1.232

53.0

FFB0412GHN -C -R00 / -F00

12

5.5 to 13.2

0.50

6.00

16500

0.662

23.39

41.6

1.638

56.0

FFB0412UHN

-C -R00 / -F00

12

5.5 to 13.2

0.65

7.80

18500

0.766

27.05

53.63

2.111

58.5

* Function type is optional.

* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.

* Noise is measured in anechoic chamber in free air, one meter from intake side.

* All readings are typical values at rated voltage.

* Specifications are subject to change without notice.

P & Q CURVE

(AT RATED VOLTAGE)

MOUNTING PANEL CUTOUT