Delta Electronics KFB1724SHS User Manual
Delta Electronics Fans
125
175 x 54 MM SERIES
KFB
DIMENSIONS DRAWING
P & Q CURVE
(AT RATED VOLTAGE)
MOUNTING PANEL CUTOUT
Bearing Type
Ball Bearings
Material
Impeller : Plastic (UL 94V-0)
Pillow :Die-Cast Aluminum
Lead Wires :
UL 1430 AWG #22 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 620g (21.87 oz)
*
*
*
*
http://www.deltaww.com
*
UNIT:
(INCH)
mm
UNIT:
(INCH)
mm
*
*
*
*
*
Function type is optional.
The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
Noise is measured in anechoic chamber in free air, one meter from intake side.
All readings are typical values at rated voltage.
Specifications are subject to change without notice.
Operating
Voltage
Range
MODEL
Rated
Voltage
Maximum
Air Flow
Speed
Maximum
Air Pressure
Noise
PART NO. FUNCTION VDC VDC Amp Watt R.P.M. CFM mmH O IN H O dB-A
2
2
KFB1724SHS
-R00 / -F00
24
14.0 to 30.0
1.65
39.60
3800
7.584
267.84
47.21
1.859
71.0
KFB1748SHS
-R00 / -F00
48
28.0 to 60.0
0.80
38.40
KFB1724EHS
-R00 / -F00
24
14.0 to 30.0
2.30
55.20
4200
8.421
297.39
56.96
2.361
73.5
KFB1748EHS
-R00 / -F00
48
28.0 to 60.0
1.15
55.20
Input
Power
Input
Current