Delta Electronics KHB1748HHT User Manual
Dimensions drawing, P & q curve, Mounting panel cutout
175 x 69 MM SERIES
KHB
DIMENSIONS DRAWING
*
*
*
Operating
Rated
Maximum
Maximum
MODEL
Voltage
Speed
Noise
Voltage
Air Flow
Air Pressure
Range
KHB1748MT
-R00/ -F00
48
32.0 to 80.0
0.36
17.28
2100
5.746
202.92
17.59
0.693
55.0
KHB1748HT
-R00/ -F00
48
32.0 to 80.0
0.57
27.36
2400
6.735
237.85
23.34
0.919
59.0
KHB1748HHT
-R00/ -F00
48
32.0 to 80.0
0.73
35.04
2700
7.132
251.87
30.70
1.209
62.5
3
PART NO. FUNCTION
VDC
VDC
Amp
Watt
R.P.M.
m /min
CFM
mmH O
IN H O
dB-A
2
2
*
P & Q CURVE
(AT RATED VOLTAGE)
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
3
(M /MIN)
(CFM)
320.0
240.0
160.0
80.0
0
Air Flow
2.4
(I
N
H
O
)
2
2
(m
m
H
O
)
2.0
1.6
1.2
0.8
0.4
0
A
ir
P
re
s
s
u
re
30.0
0
10.0
20.0
40.0
50.0
60.0
10.0
6.0
8.0
4.0
2.0
0
KHB1748XT
HH
H
M
134
Bearing Type
Ball Bearings
Material
Impeller : Plastic (UL 94V-0)
Pillow : Die-Cast Aluminum
Lead Wires :
UL 1430 AWG #22 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 670g (23.63 oz)
MOUNTING PANEL CUTOUT
http://www.deltaww.com
Input
Power
Input
Current