10

Triplett Model 9045

5: SPECIFICATIONS

5.1 Display:

0.8" (20.3mm) high LCD

5.2 Display Resolution:

6000 counts, 0000 to 5999

5.3 Overrange Indication:

Displays “OL”

5.4 Measurement Rate:

2 to 3 measurements per second

5.5 Low Battery Annunciator:

+

_

5.6 Operating Conditions:
Temperature:

0 to 40 degrees C (32 to 104 degrees F)

Relative Humidity:

less than 80%

5.7 Storage Conditions:
Temperature:

-20 to 60 degrees C (-4 to 140 degrees F)

Relative Humidity:

less than 90%

5.8 Case Dimensions:

177 x 93 x 39 mm, (L x W x H)
7.0 x 3.7 x 1.5 inches (L x W x H)

5.9 Weight:

300 grams, 0.7 lbs. (w/ battery, w/o leads)

5.10 Battery:

1 standard 9 volt alkaline battery (Triplett PN: 37-48)

5.11 Battery Life:

approx. 100 hours

5.12 Fuse:

800mA / 600 volt FAST, 5 x 20mm fuse,
for uA or mA ranges. Triplett PN: 3207-131
10A / 600 volt FAST, 1/4” x 1” fuse,
for 10A range. Triplett PN: PN 3207-128

5.13 Insulation:

Double Insulated (Protection Class II)

5.14 Approvals:

IEC 1010-1 (EN61010-1)
Overvoltage Category (Installation Category)
Category I and II to 1000 volts DC
Category I and II to 750 volts AC
Category III to 600 volts AC/DC
CE: EMC, LVD

Note:
a)
The following accuracy specifications are valid at 23 degrees C, +/- 5
degrees C, Relative Humidity less than 75%
b) The specifications are in the form “ +/- (x % of reading + LSD)” where LSD is
Least Significant Digit”.