Specifications – Triplett 9045 User Manual
Page 10

10
Triplett Model 9045
5: SPECIFICATIONS
5.1 Display:
0.8" (20.3mm) high LCD
5.2 Display Resolution:
6000 counts, 0000 to 5999
5.3 Overrange Indication:
Displays “OL”
5.4 Measurement Rate:
2 to 3 measurements per second
5.5 Low Battery Annunciator:
+
_
5.6 Operating Conditions:
Temperature:
0 to 40 degrees C (32 to 104 degrees F)
Relative Humidity:
less than 80%
5.7 Storage Conditions:
Temperature:
-20 to 60 degrees C (-4 to 140 degrees F)
Relative Humidity:
less than 90%
5.8 Case Dimensions:
177 x 93 x 39 mm, (L x W x H)
7.0 x 3.7 x 1.5 inches (L x W x H)
5.9 Weight:
300 grams, 0.7 lbs. (w/ battery, w/o leads)
5.10 Battery:
1 standard 9 volt alkaline battery (Triplett PN: 37-48)
5.11 Battery Life:
approx. 100 hours
5.12 Fuse:
800mA / 600 volt FAST, 5 x 20mm fuse,
for uA or mA ranges. Triplett PN: 3207-131
10A / 600 volt FAST, 1/4” x 1” fuse,
for 10A range. Triplett PN: PN 3207-128
5.13 Insulation:
Double Insulated (Protection Class II)
5.14 Approvals:
IEC 1010-1 (EN61010-1)
Overvoltage Category (Installation Category)
Category I and II to 1000 volts DC
Category I and II to 750 volts AC
Category III to 600 volts AC/DC
CE: EMC, LVD
Note:
a) The following accuracy specifications are valid at 23 degrees C, +/- 5
degrees C, Relative Humidity less than 75%
b) The specifications are in the form “ +/- (x % of reading + LSD)” where LSD is
“Least Significant Digit”.