beautypg.com

Tri Tool 214B Flange Facer User Manual

Page 19

background image

19

Model 214B FF (Flange Facer)

92-1503 : Orig. 100923

Problem:

There is a loss of air power

The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.

Problem:

There is a loss of hydraulic power

The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.

Problem:

The tool bit will not reach the work

Incorrect tool blocks are installed for the size of the pipe or tube being
worked on.
Incorrect tool bit is installed.

Problem:

The hydraulic motor will not start

The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.