Model 212B-FF Flange Facer

92-0291 : Rev. 921230

Problem:

There is a loss of air power

Probable causes:
The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.

Problem:

There is a loss of hydraulic power

Probable causes:
The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.

Problem:

The tool bit will not reach the work

Probable causes:
Incorrect tool blocks are installed for the size of the pipe or tube being worked on.
Incorrect tool bit is installe

d.

Problem:

The hydraulic motor will not start

Probable causes:
The hydraulic power supply is shut off.
The hydraulic motor is damaged and will not run free.