Maintenance – Tri Tool 103 REP User Manual
Page 8
8
TRI TOOL INC.
92-0131 : Rev. 960503
NOTE:
NOTE:
NOTE:
MAINTENANCE
Clean Up
All components should be cleaned and coated with a light film of oil prior to use.
Use a clean, non-detergent oil, preferably SAE 10 (90 SSU) or lighter, or oil which is
specified for the Air Motor.
AIR SUPPLY FOR THE MODEL 103 REP
TM
WITH AIR MOTOR
An adequate filter, regulator, and lubricator must be used in the air supply line.
The motor warranty is void if damage occurs from contaminated air or lack of
lubrication.
If the Model 103 REP
TM
is operated in the vertical position (Cutting Head up), it should
be turned upside down and the chips and/or other debris removed after each bevel has
been completed.
Tool life may be severely shortened, unless chips and/or other debris that have
been deposited on the Cutting Head during the machining operation are
removed.
After every 10 hours of operation the Drive Gears should be re-lubricated. See the
picture ‘Grease’.
Use TRI TOOL Inc. Lubricant (P/N 68-0019), this is a Lithium base white grease.