Beam Angles — points at which intensity drops to 50% of maximum

Lamp/Beam Data

Code: LC-44EX
Front size:
16 x 16" (40 x 40 cm)
Collapsed length: 21" (53 cm)
Max. wattage: 300
Max. amperage: 2.5 at 120v
Weight: 2.1 lbs (1 kg)
w/ 4' captive cable
U.S. Patents: 459645, 7081001,
7153153

Supplied Lamphead: TH-X300

Rifa

®

eX 44

Rifa

®

eX 55

Rifa

®

eX 66

Rifa

®

eX 88

Code: LC-55EX
Front size:
21 x 21" (53 x 53 cm)
Collapsed length: 24" (61 cm)
Max. wattage: 500
Max. amperage: 4.2 at 120v
Weight: 2.5 lbs (1.1 kg)
w/ 4' captive cable
U.S. Patents: 459645, 7081001,
7153153

Supplied Lamphead: TH-X1000

Code: LC-66EX
Front size:
25 x 25"
(63.5 x 63.5 cm)
Collapsed length: 30" (76 cm)
Max. wattage: 750
Max. amperage: 6.25 at 120v
Weight: 3.5 lbs (1.6 kg)
w/ 4' captive cable
U.S. Patents: 459645, 7081001,
7153153

Supplied Lamphead: TH-X1000

Code: LC-88EX
Front size:
32 x 32" (81 x 81 cm)
Collapsed length: 34" (86 cm)
Max. wattage: 1000
Max. amperage: 8.3 at 120v
Weight: 4.5 lbs (2 kg)
w/ 4' capt. cable
U.S. Patents: 459645, 7081001,
7153153

Supplied Lamphead: TH-X1000

Lamp Code

Volts

Watts

°K Avg Life FC(lux) 5' FC(lux) 10'

LC-44EX – Maximum 300w

JCV14.5-50WC 12/14

50 3200 100 hr

7 (80)

2 (22)

GCC

12

100 3200 100 hr

8 (81)

2 (22)

GCB

30

200 3200 100 hr

20 (220)

5 (58)

FSH

120

125 3200 100 hr

15 (166)

4 (46)

FVM

120

105 3200 250 hr

14 (148)

4 (40)

FVL**

120

200 3200 200 hr

33 (356)

9 (100)

GCA

120

250 3200 100 hr

39 (418)

10 (111)

CP/96*

120

300 3400

75 hr

49 (532)

14 (147)

GLF/P44

230

235 3200 100 hr

35 (381)

9 (102)

CP/97*

230

300 3200

75 hr

54 (582)

15 (159)

Lamp Code

Volts

Watts

°K Avg Life FC(lux) 5' FC(lux)10'

LC-55EX – Maximum 500w

EHC

120

500 3200 300 hr

72 (778)

19 (209)

EHD

120

500 3000 2000 hr

69 (745)

18 (198)

JCV 220V-500WBM 220

500 3000 2000 hr

78 (846)

21 (228)

JCV 240V-500WBM 240

500 3000 2000 hr

66 (710)

17 (188)

LC-66EX – Maximum 750w (May also use lamps for LC-55EX)
EHF

120

750

3200

300 hr 109 (1180)

30 (326)

EHG

120

750

3000 2000 hr

89 (962)

24 (262)

FKR/240

240

650

3200 300 hr

92 (990)

25 (270)

LC-88EX – Maximum 1000w (May also use lamps for LC-66EX)
FEL

120

1000

3200

300 hr 195 (2110)

56 (608)

FEP

240

1000

3200

150 hr 160 (1730)

45 (491)

FEP/240

240

1000

3200

150 hr 148 (1598)

40 (432)

LC-44EX

with 120v, 200w, 3200°K, FVL lamp

LC-55EX

with 120v, 500w, 3200°K, EHC lamp

*

Different lamp base, Rifa-44EX supplied standard

lamphead socket accepts this base.

n

Always unplug unit and allow

it to cool before lamping,
changing lampheads, storing.
n

Avoid touching glass with bare

fingers. Insert lamps carefully to
avoid breaking. Lamps must be
pressed firmly and fully into socket.
Not doing so will cause socket dam-
age and shortened lamp life.
n

Never exceed maximum

rated wattage of unit.
n

Rifa-44EX socket is designed

to accept lamps with 2 different pin
configurations. Use extra caution
when installing & removing
lamps, contacts may be stiff at
first.

LC-66EX

with 120v, 750w, 3200°K, EHF lamp

LC-88EX

with 120v, 1000w, 3200°K, FEL lamp

NOTE: Above lamps are for Standard lampheads as supplied with models of Rifa eX System and pre-2007 models of Rifa-lite.
See instructions for Accessory Lampheads or www.lowel.com for information on use and different lamp options.

It is not necessary to remove supplied Standard Lamphead when storing or transporting Rifa eX.
Remove only to exchange for accessory lampheads.

The Lowel Rifa eX is a profes-
sional lighting instrument.
Read these instructions and
lamp manufacturer’s warnings
carefully before operating.

n

Do not pull power cable

to open fixture.
n

Always operate with diffuser

safety panel in place.
n

Not for household use,

use only for photographic lighting
(film; video; imaging) purposes.
n

When setting Rifa eX up

always orient it with Warning Label
on top.
n

Do not leave Rifa eX

unattended.
n

Always unplug unit and

allow it to cool before lamping,
changing lampheads, storing.
n

Do not use more than one

diffuser, nor any diffuser other than
the Lowel Rifa diffuser supplied.
n

Make certain that lamp

voltage matches power source
voltage. The units use lamps of
different voltages (example: never
connect a 120 volt lamp to a 230 volt
source, or a Rifa-44-EX with 12 or 30
volt lamp to any higher voltage).
n

Do not exceed maximum

rated wattage for unit.
n

Make certain to attach

appropriate approved power cable
for voltage being used.
n

Do not interfere with unit’s

ventilation.
n

Never touch hot parts.

n

Units such as this emit

considerable light and heat, if not
properly used could be dangerous.
n

Avoid placing unit too close

to faces, delicate objects or
flammable materials.
n

Do not use near

standing water or in damp locations.
n

When mounting light over-

head use Safety Cables.
n

Unplug before cleaning

material. Handle reflector with care.
Clean with a damp cloth only,
as soap or chemical cleaners may
damage material. Do not operate
while fixture is damp.
n

Do not fold Diffuser when

storing. Roll it up onto supplied
cardboard tube to prevent cracking.

Lowel Rifa

®

eXchange

®

Instructions