12' AC Unswitched Cable
Code: P2-80
#18/3 cable with IEC connector is supplied with
the Pro-light to extend its captive cable.

Code: P1-80 Original AC cable for
pre-updated Pro-lights (pre-April 2003).

Optional Power Cables

To connect to international voltage or popular battery power sources,
the following adaptor cables are available from Lowel for updated (IEC)
Pro-lights (contact us for older models).

AC options

P2-801 12’ Pro Euro cable (IEC)

P2-802

12” Pro UK cable (IEC)

12 Volt battery

P2-82

1' 4-pin XLR Cable

P2-85

1' 12v Cigarette

Lighter/CarAdaptor Cable

30 Volt battery

P2-81

1' 2-pin switched 30v Cable

Power Cables & Connectors

Female

Male

1'

Female

Male

1'

Male

Female

12'

Male

Female

12'

Female

Male

1'

The Lowel Pro-light is a professional
lighting fixture. Read these instructions
and lamp manufacturer’s warnings
before operating.

n

Not for house hold use, use only for

film, video or imaging purposes.

n

Do not leave fixtures unattended.

n

Unplug fixtures when not in use.

n

The units use lamps of several different

voltages. Make certain that lamp voltage
matches power source voltage. Example: never
connect a 120 volt lamp to a 220 volt source.

n

Units such as this emit considerable

light and heat, and if not properly used, could
be dangerous.

n

Lights should not be positioned

extremely close to people. Ultraviolet light ray
emissions can cause damage to the eyes and
reddening of the skin. The likelihood of either
occurring is increased with length of exposure,
focus intensity and proximity. Therefore, lights
should be kept away from people.

n

Avoid aiming the light at, or placing

too close to, people, delicate objects or
flammable materials.

n

Do not interfere with ventilation

by covering the lights in any way.

n

For proper ventilation, do not tilt

down beyond 45 degrees or operate sideways.

n

Do not operate Pro-lights upside-

down with lamps of more than 125 watts.

n

Do not tilt Pro-light down if mounted on

top of a camera. Camera damage could result.

n

Never touch hot parts only touch

handles & knobs for light adjustments.

n

Do not touch Pro-light upper front

end knob while operating the light, high
temperature is present.

n

Do not use near standing water.

n

Avoid mounting lights directly over

people unless secured with a safety cord
or cable.

n

The updated Pro-light (2003) has an

IEC connector for its integrated AC Cable.
However older Pro-lights use a 3 pin Edison
fixed power cable which is to be used
only with the Pro-light and not as a general-
purpose extension cable.

n

Keep Pro-light power cable away

from front housing when hot, to avoid damage.

n

If battery power is used, never store

the light without first removing the power cable
from the power source.

Lowel Pro-light Instructions

Warnings

Pro-light Technical Data

Lamp/Beam Data

(Pro & i/id lamps are not interchangeable)

Performance

Slot & lock for
umbrella and
gel-frame

160° constant tension
no-yoke tilting from
stand-fitting.

4.6” (11.7 cm)

3.

7”

(

9.

4

cm

)

6.

7”

(

17

c

m

)

Front-end
comes off for
easy, no-tool
lamp change

Screw-in lock
for front-end

Focus
knob

Stand fitting
& locking
knob for 5/8”
stand tops

AC switch

Weight:

Pro w/ 4' captive cable:
1.3 lbs (590 g)
Pro w/ 4' cable & 12'
extension cable:
2 lbs (907 g)

Max. wattage: 250
Max. amperage: 8.3
Beam control: continuously variable
Fits on: 5/8" (1.59 cm) studs
Materials: primarily aluminum

and Ryton

Cable: with extension 16' (4.88 m)

#18/3. CE model with #18/2.

Switch: in-head
U.S. Patent: 4777566

Feet

5

10

15

20

25

0

5

10

5

50°

24°

10°

0

1.5

3

1.5

1.5

3

4.5

6

8

Meters

Flood
Spot
Super Spot

Beam Angles

with Clear Safety Glass

Foot Candles (Lux = foot candles x 10.8)

86

552

1139

23

143
302

11
61

135

7

34
80

4

22
47

With 120v, 200w, 3200°K,
Osram FVL lamp

Lamp

Volts Watts

°K

Avg

F. C. (lux) at 10’ (3 m)

Code

Life

Flood

Spot

Focus Range Super Spot

FVL*

120

200

3200

100 hr

23 (250)

143 (1540)

6:1

302 (3260)

FSH

120

125

3200

100 hr

11 (115)

48 (515)

4.5:1

139 (1500)

GCC

12

100

3200

100 hr

12 (125)

58 (630)

5:1

245 (2650)

JCV14.5V-50WC

12/14

50

3200

100 hr

6 (70)

28 (305)

4:1

125 (1350)

GLF/P44 ** 230

235

3200

100 hr

39 (420)

81 (880)

2:1

178 (1920)

* Replaces GCA as recommended lamp
** Only fits CE Pro-light, updated Pro-light (4/2003) & older Pro-lights with updated Front
Housing (iP2-18 )

Pro Lamp Replacement

Warning: Always unplug unit before relamping. Fixture must be cool
before lamping. Lamps must be operated at their rated voltage.
Avoid touching “glass” with bare fingers. Insert lamp carefully,
to avoid breaking.

To change lamps
1

Turn focusing knob A
to spot position.

2

Unscrew the small knob B
located on top of the front
housing. Remove front assembly.

3

Grasp porcelain socket of lamp C and rock lamp gently from side
to side while pulling straight out from fixture socket.

4

To replace lamp, hold focusing knob in spot position and insert
lamp into socket. Warning: Avoid touching the glass of the lamp
with bare fingers. Make sure lamp is well seated in the socket.
Improper insertion could result in arcing, which will shorten lamp
and socket life.

5

Replace the front housing and tighten the top knob.
Warning: Compact filament lamps such as the GCA may fail if
subject to vibration or shock while on. Turning the fixture off before
moving or adjusting
as well as operating
the focus smoothly
will help prevent
lamp failure.

A

B

C

Yes

No

Male

Female

12'