Thermon Electric Heat Tracing User Manual
Page 10
![background image](https://www.manualsdir.com/files/807588/content/doc010.png)
9
Checklist for Self-Regulating and Power-Limiting Heat Tracing
General Information
Project Number:
Installation
Contractor:
Unit Number:
Thermon Reference
Number:
Customer Ref. Number:
Inspector:
Record 1: Prior to Installation
Cable Type:
Reel Number:
Reel Length (M):
Insulation Resistance:
(M Ohms)*
Tested By/Date:
Witnessed By/Date:
Record 2: After Cable Installation
Line Number:
Thermostat Number:
Equipment Number:
Junction Box Number:
Circuit/Heater Number:
Unused Entries
Plugged Off:
Circuit Switch Number:
Heater Length (M):
Metal Sheath Connected
to Earth/Ground:
Insulation Resistance:
(M Ohms)*
Tested By/Date:
Witnessed By/Date:
Record 3: After Thermal Insulation is Installed
Insulation Watertight:
Insulation Resistance:
(M Ohms)*
Tested By/Date:
Witnessed By/Date:
Record 4: Final Commissioning
Panel Number:
Ambient Temp. (°C):
Breaker Number:
Pipe Temp. (°C):
Volts:
Recorded Amps
(after 5 min.):
Tested By/Date:
Witnessed By/Date:
*NOTE: Minimum acceptable insulation resistance should be 20 megohms for Records 1 and 2 and
5 Megohms for Record 3.