(2) Configure Synchronous Interface:
Select this option from the Main Menu to configure the synchronous interface.
(3) Configure Asynchronous Interface:
Select this option from the Main Menu to configure the asynchronous interface. (Please note : The
choices under this menu selection will be removed from WINC 2400C model, if not yet on the
screen).
(4) Configure Broadcast Interface:
Select this option from the Main Menu to change the parameters for broadcast mode. The choices
under this menu selection are described in Section 5.4.
(5) Air-Link Status:
Select this option to determine the air-link performance statistics.
(6) System Reset:
Select this option when it is required to reset the system to effect the change selected previously. The
changes that require this step are specified in the menu associated with that change. Please note that
the Main Menu is exited upon choosing this option. To get back to the Main Menu you must issue
the
(7) Exit:
Select this option to exit from the Main Menu.
5.2 Synchronous Configuration
After choosing Configure SYNCHRONOUS interface, you will see the following screen : (please
refer to fig. 5-3 for the layout of configuration manual)
Synchronous Configuration
Current speed
: 64000
Interface type
: RS-232
Tx clock source
: INTERNAL
Rx clock source
: INTERNAL
Peer Address
: XXXXXXX
Active Channel
: 0
Self Address
: XXXXXXX
SYNC Protocol
: TRANSPARENT
FEC Er Drop Pkt
: OFF
Master-Slave
: SLAVE
Air Time-Out
: 15
Air Preamble IX
: 8
Air Spreading IX
: 0
Power Level
: 4
1. Change SYNC speed
2. Change interface type
3. Change Tx clock source
4. Change Rx clock source
5. Change Peer Address
6. Change Channel Number
7. Change operation protocol
8. Change power level
9. Change FEC Check Operation
A. Change Master-Slave mode
B. Change air Time-Out value
C. Change air Preamble pattern
D. Change air Spreading Code pattern
E. Back to previous menu
Enter :