Troubleshooting – Teletronics WL11000SA-N User Manual
Page 16

User’s manual – WL11000SA-N
16
Troubleshooting
Check the following items before contacting Technical Support.
1.
If mobile users do not have roaming access to the WL11000SA-N access point, check
the following:
² Make sure that all the WL11000SA-Ns and stations in the ESS in which the WLAN
mobile users can roam are configured to the same WEP Pass Phrase, SSID and
authentication algorithm.
2.
If the WL11000SA-N cannot be configured using the web browser:
² Remove power from the WL11000SA-N.
² Do a hard reset (or load the AP’s setting to the Factory Default Setting) by inserting a
paper clip into the reset socket at the back of the WL11000SA-N. Connect the power
while holding the paper clip in place. Remove paper clip after 5 seconds.
The following table shows the supported LED patterns and functions:
Functio
n
RF Link
LED
RF Activity
LED
Action
0
OFF
OFF
- No Action, will boot normally
1
OFF
ON
- Revert to Factory Default settings.
2
ON
OFF
- Force boot from Primary code image
3
ON
ON
- Reserved, (for now will boot normally)