English – DeWalt D2002M User Manual
Page 17

17
English
CoDe
PoSSIBLe CAuSe
PoSSIBLe SoLutIon
15
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. See
extension Cords under Installation.
16
Loose electrical connections
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
17
Possible defective motor.
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
18
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit
breaker with higher rating than that specified for your
particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
19
Tank pressure exceeds pressure switch
cut-in pressure
Motor will start automatically when tank pressure drops
below
cut-in pressure of pressure switch.