CoDe

PoSSIBLe CAuSe

PoSSIBLe SoLutIon

4

Defective air tank

Air tank must be replaced. Do not repair the leak.

WARNING: Risk of bursting. Do not drill into, weld or

otherwise modify air tank or it will weaken. The air tank can

rupture or explode.

5

Leaking seals

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

6

Defective safety valve

Operate safety valve manually by pulling on ring. If valve

still leaks, it must be replaced.

7

Regulator is not adjusted correctly for accessory being

used

It is normal for some pressure drop to occur when an acces-

sory is used, adjust the regulator as instructed in

regulator

under Features if pressure drop is excessive.
note: Adjust the regulated pressure under flow conditions

while accessory is being used.

8

Prolonged excessive use of air

Decrease amount of air usage.

9

Compressor is not large enough for accessory

Check the accessory air requirement. If it is higher than

the CFM or pressure supplied by your air compressor, a

larger compressor is needed to operate accessory.

10

Hole in air hose

Replace air hose.

11

Check valve restricted

Contact a D

e

WALT factory service center or a D

e

WALT

authorized service center.

12

Air leaks

Tighten fittings.

13

Regulator is damaged

Replace.

14

Motor overload protection switch has tripped

See