English – DeWalt D2002M User Manual
Page 16
16
English
CoDe
PoSSIBLe CAuSe
PoSSIBLe SoLutIon
4
Defective air tank
Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank can
rupture or explode.
5
Leaking seals
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
6
Defective safety valve
Operate safety valve manually by pulling on ring. If valve
still leaks, it must be replaced.
7
Regulator is not adjusted correctly for accessory being
used
It is normal for some pressure drop to occur when an acces-
sory is used, adjust the regulator as instructed in
regulator
under Features if pressure drop is excessive.
note: Adjust the regulated pressure under flow conditions
while accessory is being used.
8
Prolonged excessive use of air
Decrease amount of air usage.
9
Compressor is not large enough for accessory
Check the accessory air requirement. If it is higher than
the CFM or pressure supplied by your air compressor, a
larger compressor is needed to operate accessory.
10
Hole in air hose
Replace air hose.
11
Check valve restricted
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
12
Air leaks
Tighten fittings.
13
Regulator is damaged
Replace.
14
Motor overload protection switch has tripped
See
Motor overload under Features.