English grounding instructions, Extension cords, Voltage and circuit protection – DeWalt D2002M User Manual

Page 10: Compatibility

background image

10

English

Grounding Instructions

WARNING: Risk of electrical shock. In the event of a short

circuit, grounding reduces the risk of shock by providing an escape

wire for the electric current. This air compressor must be properly

grounded.
The portable air compressor is equipped with a cord having a

grounding wire with an appropriate grounding plug.
1. The cord set and plug (J) with this unit

L

J

K

contains a grounding pin (L). This plug

MuSt be used with a grounded outlet

(K).

IMPortAnt: The outlet being used must

be installed and grounded in accordance

with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the

grounded plug. DO NOT USE AN ADAPTER.

3. Inspect the plug and cord before each use. Do not use if there

are signs of damage.

4. If these grounding instructions are not completely understood, or

if in doubt as to whether the compressor is properly grounded,

have the installation checked by a qualified electrician.

DANGER: RIsk oF elecTRIcal shock. IMPRoPeR

GRoUNDING caN ResUlT IN elecTRIcal shock.
Do not modify the plug provided. If it does not fit the available

outlet, a correct outlet should be installed by a qualified electri-

cian.

Repairs to the cord set or plug MUsT be made by a qualified

electrician.

Extension Cords

If an extension cord must be used, be sure it is:

• a 3­wire extension cord that has a 3­blade grounding plug, and

a 3-slot receptacle that will accept the plug on the product

• in good condition
• no longer than 50' (15.2 m)
• 14 gauge (AWG) or larger. (Wire size increases as gauge num-

ber decreases. 12 AWG and 10 AWG may also be used. DO

NOT USE 16 OR 18 AWG.)

Voltage and Circuit Protection

Refer to the

Voltage and Minimum Branch Circuit requirements under

Pump/Motor specifications.

CAUTION: certain air compressors can be operated on a

15 amp circuit if the following conditions are met.

• Voltage supply to circuit must comply with the National Electrical

code.

• Circuit is not used to supply any other electrical needs.
• Extension cords comply with specifications.
• Circuit is equipped with a 15 amp circuit breaker or 15 amp

time delay fuse.

NOTE: If compressor is connected to a circuit

protected by fuses, use only time delay fuses. Time delay fuses

should be marked “D” in canada and “T” in the Us.

If any of the above conditions cannot be met, or if operation of the

compressor repeatedly causes interruption of the power, it may be

necessary to operate it from a 20 amp circuit. It is not necessary

to change the cord set.

Compatibility

Air tools and accessories that are run off the compressor must be

compatible with petroleum-based products. If you suspect that a

material is not compatible with petroleum products, an air line filter

for removal of moisture and oil vapor in compressed air is required.