Main Features 

 Single or dual power supply input configuration: 

 

Single power supply configuration: 

 

 

(9 to 26) VDC, powering both controller and TE device 

 

Dual power supply configuration:  

 

 

(9 to 26) VDC at 0.15 A for controller circuitry,  

 

 

(0 to 40) VDC for TE device 

 Maximum output current: 10 A (Note: controller does not have current limiting capability) 
 Heat‐only or cool‐only control modes, selectable by jumper switch 
 Temperature  control  range:  –20  °C  to  +100  °C,  requires  the  MP‐3238  thermistor  (supplied  with  the 

controller), or its electrical equivalent 

 Best‐case control stability ±0.5 °C (when controlling a cold plate) 
 Proportional (P) bandwidth adjustment:  0.5 °C to 5.0 °C  
 Integral Rate (I) adjustment:  0 to 2.55 repeats per minute  
 Output:  Square wave, 1000 Hz, Pulse‐width modulated 
 Operating temperature range 0 °C to 50 °C ambient (with aluminum mounting plate in a vertical position 

allowing free air convection) 

 0.25 inch quick connect terminals for power, cooler, and thermistor connections 
 RoHS compliant 
 

 
The controller’s operating temperature range is 0 °C to 50 °C ambient. The range can be extended to 70 °C with 
proper heat‐sinking.  If the controller is to operate in an ambient greater than 50 °C, consult with TE Technology 
engineers  for  further  assistance.    See  “Mechanical  Package  Drawing”  for  dimensional  information  on  the 
controller. 
 
For high‐volume applications the controller can be customized: 

 Adjustment potentiometers can be replaced with preprogrammed set‐point and tuning parameters 
 Resistance versus temperature curves for other types of thermistors can be programmed 

 

This manual is related to the following products: