Simple nitrider pvt defaults, Dual loop pvt defaults – Super Systems HP15 User Manual
Page 22

HP 15 Manual Rev A
Page 22 of 22
• Analog output 1 range is 200
• First process control low limit is –100
• First process control high limit is 100
• First process control mode is such that setpoint of 0 shuts down and it is in dual mode
• Second process control low limit is 0
• Second process control high limit is 100
• Second process control mode is such that it is in single reverse
• Analog input 1 full scale is 2500
• Analog input 2 full scale is 2500
• Analog input 1 type is 2.5 volts
• Analog input 2 type is 2.5 volts
• Analog input 3 type is K thermocouple
• 20 minutes delay time before alarm
• Band +/1 for alarm in millivolts is 10
• Modbus at 9600 baud
Simple Nitrider PVT Defaults
• Process variable 1 is carbon
• Process variable 2 is temperature
• Process variable 3 is temperature
• DAC 1 is set for Hydrogen
• DAC2 is set for Dissociation
• Analog output 1 offset is 0
• Analog output 1 range is 1000
• Analog output 1 offset is 0
• Analog output 1 range is 1000
• First process control low limit is –100
• First process control high limit is 100
• First process control mode is such that setpoint of 0 shuts down and it is in dual mode
• Second process control low limit is 0
• Second process control high limit is 100
• Second process control mode is such that it is in single reverse
• Analog input 1 full scale is 2500
• Analog input 1 type is 2.5 volts
• Analog input 2 type is S thermocouple
• Analog input 3 type is K thermocouple
• host RS232
• Hitech H2 cell at 9600 baud
Dual Loop PVT Defaults
• Alarm 2 setpoint is 2000
• Alarm 3 setpoint is 2000
• Alarm 2 type is input 1 process high
• Alarm 3 type is PV2 process high