Version 1.0.7

Page 25 of 45

SMT319 User Manual

Output Flag Register

0x9007C000

31–24 23–16 15–8

7–0

OTRIGGER

R,00000000 RW,10000000 R,00000000

R,10000000

Input Flag Register

0x90054000

31–24 23–16 15–8

7–0

ITRIGGER

R,00000000 R,10000000 R,00000000

RW,10000000


Field Description

OTRIGGER Outgoing

FIFO

trigger. Set to 128 after reset.

ITRIGGER Incoming

FIFO

trigger. Set to 128 after reset.

Table 6: output flag register

OFLAG in the Video Output status register will be 1 when there are at least
OTRIGGER spaces available in the output FIFO. OTRIGGER must be programmed
with a value between 1 and 255.
IFLAG in the Video Input status register will be 1 when there are at least ITRIGGER
words in the input FIFO. This register must be programmed with a value between 1
and 255.