Viewing module details – Studio Technologies 5152 V.1 User Manual
Page 17

Model 5152 User Guide
Issue 5, September 2013
Studio Technologies, Inc.
Page 17
Model 5152
Video Generator/Audio Embedder Module
purpose input) will allow connection of an 
external switch or contact closure. This will 
then control the on/off status of the Model 
5152’s embedder function. Configuring this 
function can be performed using the Model 
5190 Remote Access Module or by way of a 
text file stored on a USB flash drive.
GPO – General-Purpose Output
Depending on the hardware version of a 
specific Model 5152 module there may be 
a GPO function available. The GPO (gen-
eral-purpose output) can be configured to 
provide a signal corresponding to the status 
of one of several Model 5152 functions. The 
GPO can be configured to be either active 
high or active low when the module’s se-
lected SDI input is correctly “locked” to the 
incoming SDI signal. The GPO can also be 
configured to be active high or active low 
when the embedder function is active. Con-
figuring this function can be performed using 
the Model 5190 Remote Access Module or 
by way of a text file stored on a USB flash 
drive.
Viewing Module Details
An associated Model 5190 Remote Access 
Module can be used to directly view firm-
ware (embedded software), hardware, and 
configuration details about a Model 5152 
module. In addition, the Model 5152 incorpo-
rates a unique standalone method of provid-
ing these details. This is accomplished by 
the module creating a simple text file which 
is stored on a USB flash drive. This file can 
then be easily viewed using a personal 
computer. Information provided in the file in-
cludes firmware version numbers, hardware 
serial number, and configuration settings. 
The information provided in the text file can 
provide assistance when configuring, using, 
and troubleshooting Model 5152 modules.
Each time a Model 5152 detects that a USB 
flash drive has been connected a text file 
will be created and stored. The file, named 
STATUS.TXT, will be stored in a folder 
named M5152 which is one level below the 
root of the USB flash drive. If the folder is 
not already present it will be created. If a 
STATUS.TXT file is already present a new 
one will automatically be written over it.
The Model 5152 does not have a method 
of accessing the current date or time, i.e., 
no real-time clock. This limitation requires 
that a fixed file creation date be used and 
12/31/1979 was selected. However, the 
time stamp continues to advance in real 
time until a power cycle occurs.
The text contained in the STATUS.TXT 
file is organized into three sections. The 
following paragraphs provide a detailed 
explanation. Refer to Figure 8 for a display 
of a sample file.
STATUS.TXT File – [SYSTEM INFO]
The [SYSTEM INFO] section of the 
STATUS.TXT file provides general informa-
tion about this specific Model 5152 module.
PRODUCT= identifies the module’s product 
type. For the Model 5152 it will be listed as 
M5152. This information is provided as a 
confirmation for situations where multiple 
STATUS.TXT files are being examined.
SERNUM= identifies the factory-assigned 
serial number of this specific module. It will 
typically be in the form of a 5-digit base-10 
number. If for some reason a serial number 
has not been factory assigned no number 
will display and the field will be blank 
(empty).