Model 760-03/77 User Guide
Issue 3, April 2015
Studio Technologies, Inc.
Page 21
for Surround
3. Use the Model 77 Control Console to
select the input source that contains the 
desired reference signal source, e.g., 
pink noise.
4. Observing the SPL meter, adjust the
Model 77’s rotary level control until the 
desired loudspeaker system reference 
level has been reached.
5. Being careful not to disturb the position
of the rotary level control, enter the con-
figuration mode by pressing and holding 
the configuration button located on the 
Model 77’s back panel.
6. Once the configuration mode has been
entered, all the monitor outputs (digital 
and analog) will mute. Press and hold 
the reference level button; its associ-
ated LED will begin to flash. After five 
seconds the LED will light steadily to 
indicate that a “snapshot” of the new ref-
erence level has been taken. The Model 
77’s numeric display will then show the 
value of the new reference level. The 
value shown will always be a negative 
number as it’s always a value less than 
the maximum output level. The refer-
ence level button can now be released.
7. To complete the process the configura-
tion mode must be exited. This is per-
formed by again pressing and holding 
the configuration button for two seconds. 
The new reference level is now stored in 
the Model 760-03’s nonvolatile memory. 
Only by repeating the entire procedure 
can the value be changed.
Once the configuration mode has been ex-
ited, the digital and analog monitor outputs 
will again become active. Confirm that the 
correct level has been stored by pressing 
the reference level button. The SPL meter 
should display the desired level. If not, 
repeat the calibration procedure to achieve 
the desired goal.
You might wonder why you have to press 
and hold the reference level button for 
five seconds before the selected value is 
recognized. This is provided specifically so 
that unauthorized users won’t accidentally 
change the reference level while they ex-
periment with the configuration mode. Only 
if you know the “secret” will you be able to 
store a new value.
Overall Display Mode
The Model 77’s 4-digit numeric display 
can be configured to display the post-fader 
digital and analog monitor output levels 
in either an attenuation mode or an SPL 
mode. In the attenuation mode the output 
level is shown as a reduction in level, in 
dB, relative to the maximum output level. 
When the rotary control is used to set the 
output level to its maximum the display will 
show 0.0. As the rotary control is turned in 
the counterclockwise direction the display 
will show negative values, reaching –70.0 
before the full mute function automatically 
mutes the monitor outputs.
In the SPL mode the display can be con-
figured to allow the output level to be 
presented to users in terms of the actual 
sound pressure level (SPL). It is used in 
conjunction with the reference level in dB 
SPL configuration and the stored reference 
level. The SPL mode allows a user to see 
a visual representation of the SPL level 
that is present in the listening environment. 
While it takes a little more care to correctly 
implement the SPL display mode, it can 
offer an enhanced experience for Studio-
Comm users.