Skutt EnviroVent User Manual
Page 13

13
VII
REFERENCE
The EnviroVent
is a UL listed accessory when used with the following Skutt UL listed kilns.
Models
1227-3
240 or 208 volt
1227-3
240 or 208 volt
3 phase
1027-3
240 or 208 volt
1027-3
240 or 208 volt
3 phase
1027
240 or 208 volt
1027
240 or 208 volt
3 phase
1018-3
240 or 208 volt
1018
240 or 208 volt
818-3
240 or 208 volt
818
240 or 208 volt
818P-3
240 or 208 volt
818P
240 or 208 volt
KM818-30A-3
240 or 208 volt
NOTE: All of the above kilns may have a prefix of KM or KS.
VIII
SPECIFICATIONS
Motor: 115 volt
1.1 amps
0.18 horsepower
Heat exiting blower: 160
F maximum
Static pressure: 0.2 inches
distances greater than 60 ft: 0.4 inches
Blower: 60-80 cfm
distances greater than 60 ft: 60 cfm
Maximum kiln capacity for use with EnviroVent
: 14 cubic feet
Plate: 23” across