4 “Cold” spot near top
of kiln
lid holes too close together
shelf too close to top of kiln
plug lid holes and redrill at proper
spacing - see diagram
lower shelf
5 Blower motor does
not run
switch is turned off
not plugged in
circuit breaker tripped or fuse
blown
motor or wiring burnt out
turn in-line switch on
plug into 115v outlet
check room electrical panel
replace motor
6 Bisque fires with
black or gray interior
insufficient venting
increase ventilation or reduce size of
load
7 Black particles of
carbon when firing
wax resist
insufficient venting
reduce amount of wax resist or increase
ventilation
8 Heating elements
pitted or metal appears
discolored
insufficient venting
reduce organic or sulphur content in
bodies or increase ventilation
9 Vibration of kiln
kiln stand is not level
blower mounting loose
motor bearings damaged
impeller blades off balance due
to accumulated debris
level kiln stand
tighten mounting firmly
replace motor
use a compressor to blow out debris
If you determine a hole needs to be closed, obtain some firebrick patching material or ceramic
fiber from your local ceramic distributor. A paste made of high temperature kiln wash is also
acceptable for patching. When making the repair, force the material into the hole from both sides
of the hole. Allow to dry before firing.
VI
SERVICE
When service is required
If your EnviroVent
requires service, contact your dealer, distributor or Skutt Ceramic
Products, Inc.