To Calibrate the Barometric Pressure

2) To be able to read the current barometric
pressure as a pressure referring to sea-level
although at an altitude, calibrate as follows:

Check the current altitude (for example 1000m).
Divide 1000/8 (since 1 hPa/mbar is 8m altitude).
Result 125 hPa/mbar. Set offset to +125hPa/mbar.
The reading will now refer to the pressure at sea-
level.

!

!

!

!

Following the previous 'Setting the Storm Alarm'
section to select the Calibration Display.

In the Calibration Display, press and hold the
[reset] button for 2 seconds to select the
Calibration Setting Display.

When the 'offset value' digits are flashing, press
the [set] or [reset] button to scroll to select the
target offset value (hold down the button to scroll
the setting at a faster pace).

When the above settings finished, press the
[mode] button once to exit the setting sequence.

1) When the barometric pressure has been
calibrated, the current barometric pressure w i l l
offset by the target offset value.

Setting Pressure relative to Sea Level

Barometer Mode -

Calibrating the Barometric Pressure

13.5

Calibration Setting Display

Pressure Calibration Display

hold [reset]

[set]

hold [set]

[mode]

[reset]

hold [reset]

Select the

setting by

backward scrolling

Select the

setting by

forward scrolling

Select the setting by

backward scrolling

(fast scrolling)

Select the setting by

forward scrolling

(fast scrolling)

1001.3

0.0

OFFSET

BARO hPa

1001.3

0.0

OFFSET

BARO hPa

the offset
value

the current
value