Application worksheet, Example – Sensoray 417 User Manual
Page 7

Instruction Manual
6
Example
Set the base address to 0390:
Nibble3 = 0, so install A15-A12.
Nibble2 = 3, so install A11-A10 and remove A9-A8.
Nibble1 = 9, so install A6-A5 and remove A7 and A4.
Nibble0 = 0, so install A3-A1.
Application Worksheet
Use this worksheet to record and configure the Model 417 base address for your application.
1. Enter your target base address, in hexadecimal, in the space provided below:
2. Copy the hexadecimal address digits from the above box into the corresponding nibbles in the
spaces provided below. As in the example shown above, and using the Option Shunt Table as a
guide, darken in the circles representing option shunts that must be installed for each nibble.
3. Program the Model 417 circuit board option shunts as shown in the above table.
Nibble3 = 0
Nibble2 = 3
Nibble1 = 9
Nibble0 = 0
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
l
l
l
l
l
l
m
m
m
l
l
m
l
l
l
Base Address:
Nibble3 =
Nibble2 =
Nibble1 =
Nibble0 =
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m