beautypg.com

Application worksheet, Example – Sensoray 417 User Manual

Page 7

background image

Instruction Manual

6

Example

Set the base address to 0390:

Nibble3 = 0, so install A15-A12.
Nibble2 = 3, so install A11-A10 and remove A9-A8.
Nibble1 = 9, so install A6-A5 and remove A7 and A4.
Nibble0 = 0, so install A3-A1.

Application Worksheet

Use this worksheet to record and configure the Model 417 base address for your application.

1. Enter your target base address, in hexadecimal, in the space provided below:

2. Copy the hexadecimal address digits from the above box into the corresponding nibbles in the
spaces provided below. As in the example shown above, and using the Option Shunt Table as a
guide, darken in the circles representing option shunts that must be installed for each nibble.

3. Program the Model 417 circuit board option shunts as shown in the above table.

Nibble3 = 0

Nibble2 = 3

Nibble1 = 9

Nibble0 = 0

A15

A14

A13

A12

A11

A10

A9

A8

A7

A6

A5

A4

A3

A2

A1

l

l

l

l

l

l

m

m

m

l

l

m

l

l

l

Base Address:

Nibble3 =

Nibble2 =

Nibble1 =

Nibble0 =

A15

A14

A13

A12

A11

A10

A9

A8

A7

A6

A5

A4

A3

A2

A1

m

m

m

m

m

m

m

m

m

m

m

m

m

m

m