beautypg.com

Hardware configuration 3, Base address – Sensoray 417 User Manual

Page 6

background image

Chapter

3

Hardware Configuration

3

Base Address

Before you install the coprocessor board in your system, its base I/O address must be set. The
base address may be set to any even value in the range 0000 to FFFE (hexadecimal) by means
of option shunts A1 through A15. These option shunts are factory set to locate the board at
address 02B2 and 02B3. To avoid conflicts, you must map the 417 into a two-port address
range that is unoccupied by other devices.

Option Shunt Table

If you require the 417 board to have a base address different from the default address , use the
following table to help to determine the proper shunt settings:

Table 3: I/O address jumpers:

l = install shunt, m = remove shunt

N

ib

b

le

V

a

lu

e

High Address Byte

Low Address Byte

Nibble3 (high)

Nibble2

Nibble1

Nibble0 (low)

A15

A14

A13

A12

A11

A10

A9

A8

A7

A6

A5

A4

A3

A2

A1

0

l

l

l

l

l

l

l

l

l

l

l

l

l

l

l

1

l

l

l

m

l

l

l

m

l

l

l

m

2

l

l

m

l

l

l

m

l

l

l

m

l

l

l

m

3

l

l

m

m

l

l

m

m

l

l

m

m

4

l

m

l

l

l

m

l

l

l

m

l

l

l

m

l

5

l

m

l

m

l

m

l

m

l

m

l

m

6

l

m

m

l

l

m

m

l

l

m

m

l

l

m

m

7

l

m

m

m

l

m

m

m

l

m

m

m

8

m

l

l

l

m

l

l

l

m

l

l

l

m

l

l

9

m

l

l

m

m

l

l

m

m

l

l

m

A

m

l

m

l

m

l

m

l

m

l

m

l

m

l

m

B

m

l

m

m

m

l

m

m

m

l

m

m

C

m

m

l

l

m

m

l

l

m

m

l

l

m

m

l

D

m

m

l

m

m

m

l

m

m

m

l

m

E

m

m

m

l

m

m

m

l

m

m

m

l

m

m

m

F

m

m

m

m

m

m

m

m

m

m

m

m