Stream Control
Stream control window allows individual network configuration and control of each of
the two streams.
The “Current” section displays the stream status and allows starting and stopping the
stream.
The “Settings” section configures the following stream parameters:
Destination: an IP address of the destination host.
Port: network port of the destination host.
Retry timeout: determines the length of time (in seconds) during which the 3011 tries to
obtain destination's ARP entry.
Packet Headers: allows the choice of no headers, a 2 byte sequence counter, or a
multicast B2 frame.