For the operator – Scotsman RS160 User Manual
Page 15

Replenishing CO
2
Supply
Note: When indicator on CO
2
cylinder regulator
1800 psi gauge is in the shaded area, the cylinder
is almost empty and should be changed.
1. Fully close (clockwise) CO
2
cylinder valve.
2. Slowly loosen CO
2
regulator assembly coupling
nut allowing CO
2
pressure to escape, then remove
regulator assembly from CO
2
cylinder.
3. Unfasten safety chain and remove empty CO
2
cylinder.
4. Position CO
2
cylinder and secure with safety
chain.
5. Make sure gasket is in place inside CO
2
regulator coupling nut, then install regulator on
CO
2
cylinder.
6. Open (counterclockwise) CO
2
cylinder valve
slightly to allow lines to slowly fill with gas, then
open valve fully to back seat valve. (Back seating
valve prevents leakage around valve shaft.)
7. Check CO
2
connections for leaks. Tighten loose
connections.
Replenishing Syrup Supply.
1. Remove CO
2
disconnect and syrup disconnect
from empty syrup tank, then remove tank.
2. Place full syrup tank in position, then connect
CO
2
disconnect and syrup disconnect to full syrup
tank.
Syrup Flavor Change.
Contact beverage supplier to have soda circuit
sanitized.
If the CO
2
tanks falls
over, valve can
become damaged or broken off, this can
cause serious injury.
To avoid personal injury and/or property damage,
always secure CO
2
cylinder with a safety chain to
prevent it from falling over.
FOR THE OPERATOR
RS160 and RS220
June 1995