beautypg.com

Circuit board testing, Nse650 – Scotsman NSE650 User Manual

Page 31

background image

CIRCUIT BOARD TESTING

INSTRUCTIONS FOR USING TESTER (Optional,
order part no. A33942-001)
(These instructions assume that the unit will not run,
and prior investigation of electric power, controls, and
mechanical parts indicates that the electronic circuit
may be at fault.)

If the "Reset" indicator (located in the "reset" switch) is off and the "NO WATER" indicator is lit, but
inspection shows that the water level in the reservoir is above the top of the water level sensor, OR the
"BIN EMPTY" indicator is off while inspection shows that the ice level sensors are properly aligned, clean
and not obstructed, use the tester as follows:
Bin Control

Note: All testing is done with the

electrical power on, the master switch on, and all
reset switches “reset”.
1. Unplug “photo trans” and “LED” connectors from
the circuit board.
2. Plug “photo trans” and “LED” connectors from
the tester into the circuit board.

a. Move the “bin full” switch on the tester to Full.

The light on the tester should be ON.
If the light on the tester is not on, the circuit board
should be replaced.

b. If the light on the tester IS on, move the “bin

full” switch to Bin Empty. The light on the tester
should go OFF, and the Bin Empty light on the
circuit board should go ON.
If the Bin Empty light is ON, wait 10-20 seconds for
the machine to start, if the machine starts, replace
the ice level sensors.
If the Bin Empty light does not come ON, the
circuit board should be replaced.

PHOTO TRANS

LED

LIGHT GOES

ON

SWITCH TO

"FULL"

LIGHT GOES

ON

LIGHT

GOES OFF

SWITCH TO

"BIN EMPTY"

Electrical Shock Hazard.
Electrical shock can
cause personal injury.
Disconnect electrical
power before connecting
tester.

NSE650

August 1993

Page 31