beautypg.com

Nse650, Maintenance and cleaning – Scotsman NSE650 User Manual

Page 16

background image

1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.

3. The bearing in the breaker should also be
checked at least two times per year.

A. Check the bearing by:

••

removing the ice chute cover

••

unscrewing the ice sweep

••

removing the water shed

••

unscrewing the breaker cover.

••

unscrewing the auger stud

Inspect the assembly, looking for wear.
See Removal and Replacement to replace
bearing or seals. Reverse to reassemble.
4. Check and tighten all bolts and screws.

CLEAN THE

WATER LEVEL

PROBE

PULL UP TO

REMOVE PROBE

RESERVOIR

///////////////////////////////////////////

CAUTION: THE TIP IS

MADE OF GLASS

//////////////////////////////////////////

ICE LEVEL SENSORS:

SLIDE UP TO REMOVE

CLEAN THE

LIGHT

SENSORS

MAINTENANCE AND CLEANING

ICE SWEEP

BREAKER

COVER

Moving Parts Hazard.
Rotating Auger can
cause personal injury.
Disconnect electrical
power before beginning.

NSE650

June 1994

Page 16