COMPONENT LOCATION: Control Box

Auger Delay Pressure Control: This pressure
switch, connected to the low side of the
refrigeration system, controls the auger drive
motor.

High Pressure Control: The pressure switch,
used on water cooled models only, is designed to
open and shut off the machine should the high
side refrigeration pressure become too high,
usually as a result of not enough water through the
water cooled condenser.

It is a manual reset.

On-Off switch: This toggle
switch shuts off the machine. It is
not a complete disconnect.

Bin Thermostat: This thermostat
turns the machine on and off in
response to changes in
temperature of the capillary tube.
It opens at 35

0

F. and closes at

45

0

F. The capillary tube is

mounted on the inside of the ice
chute.

On-Off Switch

High Pressure

Control

Auger Delay Control

Bin Thermostat

MFE400