FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet
Air Cooled: The recommended water supply is
cold water. Use 3/8" O.D. copper tubing, connect
to the 3/8" male flare at the back of the cabinet.
Install a hand valve near the machine to control
the water supply.

Water Cooled: A separate

3

8

" O.D. copper tube

should be connected to the condenser inlet, with a
separate hand valve to control it.
Drains

Air cooled: There is one

7

16

" I.D.

hose to connect to for a drain. This
drain is a gravity drain, and a
minimum of

1

4

" per foot fall is needed

for horizontal portions of the drain
line.
The ideal drain receptacle is a
trapped and vented floor drain.
Use only rigid tubing.
Water Cooled Models: In addition to
the above mentioned drain, separate
condenser drain must be installed.
Connect to the

3

8

" condenser drain

tube.
Storage Bin: A separate gravity type
drain needs to be run. This drain line
should be insulated.

CONDENSER

WATER INLET

(Water Cooled)

OVERFLOW

DRAIN

POTABLE WATER

INLET

WATER FILTER

(FIELD SUPPLIED)

CONDENSER DRAIN

(Water Cooled)

BIN DRAIN

FLOOR

DRAIN GRILL