For the plumber, Mfe400, Conform to all applicable codes – Scotsman MFE400 User Manual
Page 5

FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Air Cooled: The recommended water supply is
cold water. Use 3/8" O.D. copper tubing, connect
to the 3/8" male flare at the back of the cabinet.
Install a hand valve near the machine to control
the water supply.
Water Cooled: A separate
3
⁄
8
" O.D. copper tube
should be connected to the condenser inlet, with a
separate hand valve to control it.
Drains
Air cooled: There is one
7
⁄
16
" I.D.
hose to connect to for a drain. This
drain is a gravity drain, and a
minimum of
1
⁄
4
" per foot fall is needed
for horizontal portions of the drain
line.
The ideal drain receptacle is a
trapped and vented floor drain.
Use only rigid tubing.
Water Cooled Models: In addition to
the above mentioned drain, separate
condenser drain must be installed.
Connect to the
3
⁄
8
" condenser drain
tube.
Storage Bin: A separate gravity type
drain needs to be run. This drain line
should be insulated.
CONDENSER
WATER INLET
(Water Cooled)
OVERFLOW
DRAIN
POTABLE WATER
INLET
WATER FILTER
(FIELD SUPPLIED)
CONDENSER DRAIN
(Water Cooled)
BIN DRAIN
FLOOR
DRAIN GRILL
MFE400
September 2005
Page 5