beautypg.com

Model identifications, Dispenser model identification – Scotsman IS100 User Manual

Page 3

background image

DISPENSER MODEL IDENTIFICATION

The complete model number of the dispenser describes many of its options:

IS

100

E

-L

F

-1

A

Type

Bin

Cabinet

Activation

Display

Voltage

Series

Capacity

Finish

Method

Type

In this example, the IS100E-LF-1A is an Ice Station with 100 lb. storage; it’s painted; uses levers for
dispensing; does have a lighted display; is 115 volt; and is the first series.

TYPE: IS = Ice Station. BIN CAPACITY: 100 = 100 lb. 150 = 150 lb. CABINET FINISH: E = Painted S =
Stainless. ACTIVATION METHOD: B = Push Button for ice L = Push Lever for ice. DISPLAY TYPE: F =
Lighted front panel N = No light. VOLTAGE: -1 = 115/60/1. SERIES: Design changes in alphabetical
sequence. Other variations may include brand identification.

FOR THE INSTALLER: Installation of Loose Shipped Parts

Sink:

1. Remove splash panel from unit.

2. Slip a worm drive clamp over the drain tube as
shown.

3. Hold the drip tray up at an angle of about 30

o

.

Slide the drain fitting into the drain tube.

4. Tighten the worm-drive clamp.

5. Hang the drip tray onto the mounting tabs at the
base of the unit. Replace the splash panel.

Ice Lever*, Ice chute, and Fluorescent Tube*

1. Slide out the
ice chute
mounting panel.

2. Insert the ice
lever into the
slot as shown.

3. Swing the
lever through
the slot from
right to left and
let it hang freely.

4. Twist the
fluorescent tube into the sockets.

5. Replace the ice chute mounting panel.

6. Insert the ice
chute into the
panel and twist
clockwise 1/3
turn.

7. Attach the
upper front
cover by
pushing the
strikes on the
cover into the
catches on the
unit.

* Optional depending upon unit configuration.

LEVER

SLOT

ICE CHUTE
MOUNTING

PANEL

ICE CHUTE

MOUNTING

TABS

DRAIN

FITTING

SINK

DRAIN

TUBE

SPLASH

PANEL

IS100 and IS150

October 1993

Page 3